DX series
Flameproof (Ex db) permanent-magnet AC servo motors with square flange and resolver feedback. Five types in three frame sizes.
Product rendering. Configuration and appearance may change.
Key data
Ratings and mounting interface of the five types. Scroll the table sideways on a small screen.
| Type | 70DX040C | 90DX100C | 130DX150C | 130DX260C | 130DX380C |
|---|---|---|---|---|---|
| Ratings | |||||
| Rated power Pn (kW) | 0.40 | 1.00 | 1.50 | 2.60 | 3.80 |
| Rated torque Tn (N·m) | 1.27 | 3.18 | 6 | 10 | 15 |
| Peak torque Tmax (N·m) | 3.81 | 9.9 | 18 | 25 | 30 |
| Rated speed nn (rpm) | 3000 | 3000 | 2500 | 2500 | 2500 |
| Maximum speed nmax (rpm) | 5000 | 4500 | 2800 | 2800 | 2800 |
| Rated voltage Un (V AC) | 220 | 220 | 220 | 380 | 380 |
| Rated current In (A rms) | 2.9 | 4.5 | 6.0 | 5.9 | 7.4 |
| Peak current Imax (A rms) | 8.7 | 13.5 | 18 | 17.8 | 22.5 |
| Overall length incl. shaft, without brake (mm) | 240.2 | 298.5 | 289.5 | 319.5 | 341.5 |
| Mounting interface | |||||
| Frame | DX70 | DX90 | DX130 | DX130 | DX130 |
| IEC flange number | 75 | 100 | 165 | 165 | 165 |
| Flange, square across flats (mm) | 70 | 85 | 136 | 136 | 136 |
| Spigot Ø × length (mm) | Ø60 j6 × 2.5 | Ø80 j6 × 3.0 | Ø130 j6 × 3.5 | Ø130 j6 × 3.5 | Ø130 j6 × 3.5 |
| Shaft Ø × length (mm) | Ø11 j6 × 23 | Ø19 j6 × 40 | Ø24 j6 × 50 | Ø24 j6 × 50 | Ø24 j6 × 50 |
| Protection and marking | |||||
| Degree of protection | IP65 | IP65 | IP65 | IP65 | IP65 |
| Ambient temperature (°C) | −20 … +40 | −20 … +40 | −20 … +40 | −20 … +40 | −20 … +40 |
| Ex marking | II 2 G Ex db IIC T5 Gb II 2 D Ex tb IIIC T100 °C Db | II 2 G Ex db IIC T4 Gb II 2 D Ex tb IIIC T130 °C Db | |||
Data from the technical manual BA-DX-EN-V7.0 (edition 2026-11). Marking as stated on the certificates. Where the nameplate differs from this table, the nameplate takes precedence.
Common features
- Flameproof aluminium housing. Two M20 × 1.5 Ex d cable entries, with Ex d cable glands fitted as standard.
- Permanent-magnet AC servo motor with four pole pairs, rated for continuous duty S1.
- Natural convection cooling. No fan is fitted and none may be added.
- Insulation class F, degree of protection IP65.
- PTC thermal protection in the winding.
- Mounting IM B5. IM V1 and IM V3 are permitted.
- Keyed shaft, key fitted.
Options
Holding brake
Optional spring-applied brake, 24 V DC. Holding torque data on request.
Feedback
Resolver (code R) is standard. A SICK SKM36 HIPERFACE mechanical multiturn absolute encoder (code E, no battery) is available as an option. The feedback device is inside the flameproof enclosure and cannot be changed in the field.
Documents
The technical manual BA-DX-EN-V7.0, the product sheet and the certificates are in the downloads. Outline drawings are in preparation; the mounting dimensions are in Chapter 12 of the manual.